Mostrar el registro sencillo del ítem

dc.contributor.advisorRobles Castillo, Heber Maxes_PE
dc.contributor.authorYupanqui Pérez, Jesús Bernardoes_PE
dc.date.accessioned2022-08-18T19:02:42Z
dc.date.available2022-08-18T19:02:42Z
dc.date.issued2022-08
dc.identifier.urihttp://dspace.unitru.edu.pe/handle/UNITRU/19930
dc.description.abstractEl presente trabajo de Suficiencia Profesional como Bachiller en Ciencias Biológicas se realizó en el Laboratorio de Análisis Clínicos Santa Verónica, realizando pruebas de hematología, bioquímica, inmunología y microbiología. El estudio tuvo como objetivo determinar la frecuencia de las diferentes muestras procesadas y la incidencia de casos positivos en el total de muestras durante 3 años en el periodo 2017 – 2019. Donde se analizaron un total de 7310 muestras para análisis clínicos diferentes, de las cuales 2100 correspondieron a análisis bioquímicos,1230 hematológicos, 1950 inmunológicos, 1050 análisis de orina, 980 coproparasitológicos. Se encontró que en los análisis bioquímicos el perfil lipídico presentó la frecuencia fue de 38.1% , la determinación de glucosa 33.3% y en menor porcentaje perfil hepático 28.6 % . Se estableció que la frecuencia de las pruebas dentro de los valores normales fueron el 63% en perfil lipídico 75% perfil hepático, 69 % para glucosa. En los análisis hematológicos el 61% correspondieron a hemograma completo y 39% para hemoglobina glicosilada. En relación a hemograma completo se encontró que el 80% están dentro de los valores normales y en la prueba de hemoglobina glicosilada del 20% estuvieron dentro de los valores normales. En los análisis inmunológicos, el 12.8 % correspondieron a pruebas de VDRL, el 15.4 % a pruebas de antiestreptolisina, 20.5% a determinación de factor reumatoideo, 18% a pruebas de proteína C reactiva y el 33.3% a pruebas de determinación de embarazo. En el análisis de orina el 74% correspondieron a examen de orina completa y el 26% a urocultivo. De las muestras de urocultivo positivas a bacterias se encontraron Escherichia coli, Proteus sp, Pseudomonas sp. De los análisis coproparasitológicos se encontró que 65% correspondieron a examen directo, 27 % a Test de GRAHAM y el 8% a examen de THEVENON. Se concluye que los análisis más frecuentes realizados fueron perfil lipídico con 38.1% (800/2100), hemograma completo 61% (750/1230), exámenes de prueba de embarazo con 33.3% (650/1950), examen de orina completo 74%(780/1050) y examen coproparasitológico directo 65% (640/980).es_PE
dc.description.abstractThe present work of Professional Sufficiency as a Bachelor of Biological Sciences was carried out in the Santa Verónica Clinical Analysis Laboratory, carrying out hematology, biochemistry, immunology and microbiology tests. The objective of the study was to determine the frequency of the different samples processed and the incidence of positive cases in the total samples during 3 years in the period 2017 - 2019. Where a total of 7310 samples were analyzed for different clinical analyses, of which 2,100 corresponded to biochemical analyses, 1,230 hematological, 1,950 immunological, 1,050 urinalysis, and 980 coproparasitological. It was found that in the biochemical analyzes the lipid profile presented the frequency was 38.1%, the determination of glucose 33.3% and in a lower percentage hepatic profile 28.6%. It was established that the frequency of tests within normal values was 63% in lipid profile, 75% liver profile, 69% for glucose. In the hematological analysis, 61% corresponded to complete blood count and 39% to glycosylated hemoglobin. In relation to the complete blood count, it was found that 80% are within normal values and in the glycosylated hemoglobin test, 20% were within normal values. In the immunological analyses, 12.8% corresponded to VDRL tests, 15.4% to antistreptolysin tests, 20.5% to rheumatoid factor determination, 18% to C-reactive protein tests, and 33.3% to pregnancy determination tests. In the urinalysis, 74% corresponded to a complete urine test and 26% to urine culture. Of the urine culture samples positive for bacteria, Escherichia coli, Proteus sp, Pseudomonas sp. Of the coproparasitological analyzes it was found that 65% corresponded to direct examination, 27% to the GRAHAM test and 8% to the THEVENON examination. It is concluded that the most frequent analyzes performed were lipid profile with 38.1% (800/2100), complete blood count 61% (750/1230), pregnancy test exams with 33.3% (650/1950), complete urinalysis 74%. (780/1050) and direct coproparasitological examination 65% (640/980).es_PE
dc.formatapplication/pdfes_PE
dc.language.isospaes_PE
dc.publisherUniversidad Nacional de Trujilloes_PE
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.sourceUniversidad Nacional de Trujilloes_PE
dc.subjectSuficiencia profesionales_PE
dc.subjectAnálisis clínicoses_PE
dc.subjectMuestras sanguíneases_PE
dc.subjectDiagnostico, frecuencia.es_PE
dc.titleFrecuencia de análisis clínicos en el laboratorio Santa Verónica - Trujillo - La Esperanza, La Libertades_PE
dc.typeinfo:eu-repo/semantics/monographes_PE
thesis.degree.nameBiólogo-Microbiólogoes_PE
thesis.degree.disciplineMicrobiología y Parasitologíaes_PE
thesis.degree.grantorUniversidad Nacional de Trujillo.Facultad de Ciencias Biólogicases_PE
dc.type.versioninfo:eu-repo/semantics/publishedVersiones_PE
dc.publisher.countryPEes_PE
renati.advisor.dni32770121
renati.advisor.orcidhttps://orcid.org/0000-0003-2967-7595es_PE
renati.author.dni18854010
renati.typehttp://purl.org/pe-repo/renati/type#trabajoDeSuficienciaProfesionales_PE
renati.levelhttp://purl.org/pe-repo/renati/nivel#tituloProfesionales_PE
renati.discipline511146es_PE
renati.jurorGonzales Varas,Adalberto Javieres_PE
renati.jurorWilson Krugg, Juan Hectores_PE
renati.jurorLujan Velasquez, Manuela Natividades_PE
dc.subject.ocdehttp://purl.org/pe-repo/ocde/ford#1.06.00es_PE


Ficheros en el ítem

Thumbnail
Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

info:eu-repo/semantics/openAccess
Excepto si se señala otra cosa, la licencia del ítem se describe como info:eu-repo/semantics/openAccess
Universidad Nacional de Trujillo

Av. Juan Pablo II S/N Urb. San Andrés Trujillo – La Libertad, Perú | Telf. (044) 209020

Todos los contenidos de dspace.unitru.edu.pe están bajo la Licencia Creative Commons

repositorio@unitru.edu.pe / wlopez@unitru.edu.pe