"Influencia del porcentaje de residuo de filtro de celulosa en reemplazo del valor agregado fino sobre la calidad y durabilidad en unidades de albiñalería de concreto"

dc.contributor.advisorVásquez Alfaro, Iván Eugenio
dc.contributor.authorAcuña Castañeda, Manuel Andres
dc.contributor.authorNuñez Quiroz, Fiorella Raquel
dc.date.accessioned2024-11-06T19:15:53Z
dc.date.available2024-11-06T19:15:53Z
dc.date.issued2024-11
dc.description.abstractLa emisión de contaminantes de los filtros de aire de celulosa de vehículos es relevante para el medio ambiente. Estos atrapen partículas y sustancias nocivas para proteger el motor, pero su descomposición, puede tardar años y liberar partículas que contaminan el ambiente. La presente investigación, desarrollada en la Universidad Nacional de Trujillo, se busca evaluar el reemplazo del filtro de celulosa en ladrillos de concreto tipo V sobre la resistencia a la compresión (NTP 339.601), densidad (NTP 399.604), absorción (NTP 399.604), degradación térmica (NCh935/1), degradación fúngica (ASTM C21), Para el diseño de mezcla se usó el método ACI 211, para lo cual se empleó cemento portland tipo ICo Extraforte de la empresa Pacasmayo con una cantidad de 332 kg⁄m^3 , arena 999 kg⁄m^3 , confitillo 3/8" - 699 kg⁄m^3 , agua 226 lts, considerando una relación agua/cemento de 0,60 y se sustituyó agregado tino por volumen de pulpa de filtro de celulosa al 0,40, 50, 60, 70 y 80%. Para los ensayos en estado endurecido se elaboraron ladrillos tipo V con dimensiones de 22 cm x 13 cm x 9 cm ajustando la relación a/c de 0.50 en la mezcla y se evaluó a 28 días de curado por aspersión con agua potable según lo indicado en las normas empleadas. Adicionalmente a ello, se realizó la evaluación de ladrillos de concreto de la empresa UNICON para una posterior comparación de resultados. Se observó que los ladrillos elaborados con el diseño patrón tenían una resistencia a la compresión de 191 kg⁄〖cm〗^2 , densidad 2263 kg⁄m^3 , absorción 5 %, degradación térmica de 11,60 g, sin observar presencia de hongo, mientras que con el reemplazo del 50% del agregado fino por pulpa de filtro de celulosa se obtuvo una resistencia a la compresión de 182 kg⁄〖cm〗^2 . densidad kg⁄m^3 ,, absorción 7 %, degradación térmica de 13 96 g, sin apariencia de hongo. Se determinó que la incorporación de mayor porcentaje de filtro disminuye la resistencia a la compresión en 157 kg⁄〖cm〗^2 , asi como también la densidad en 2033 kg⁄m^3 , absorción en 9 %, sin embargo, aumenta la degradación térmica en 15,97 g y se mantiene la ausencia de hongo. En base al análisis de resultades obtenidos en la investigación, se establece que el porcentaje óptimo de remplazo es del 50 % de residuo de Filtro de celulosa respecto al volumen del agregado fino, esto representaría un 6% de residuo de filtro de celulosa y 94% de agregado fino con respecto al peso. Palabras clave: filtro de celulosa, ladrillo de concreto, papel reciclado. ABSTRACT The emission of pollutants from vehicle cellulose air filters is relevant to the environment. These trap particles and harmful substances to protect the engine, but their decomposition can take years and release particles that pollute the environment. The present research, developed at the National University of Trujillo, seeks to evaluate the replacement of the cellulose filter in type V concrete bricks on compression resistance (NTP 339.601), density (NTP 399.604), absorption (NTP 399.604), thermal degradation (NCh935/1), fungal degradation (ASTM C21), For the mix design the ACI 211 method was used, for which Portland cement type ICo Extraforte from the Pacasmayo company was used with an amount of 332 kg⁄m^ 3, sand 999 kg⁄m^3, confitillo 3/8" - 699 kg⁄m^3, water 226 liters, considering a water/cement ratio of 0.60 and fine aggregate was replaced by volume of cellulose filter pulp at 0.40, 50, 60, 70 and 80%. For the tests in the hardened state, type V bricks with dimensions of 22 cm x 13 cm x 9 cm were made, adjusting the w/c ratio of 0.50 in the mixture and evaluated after 28 days of curing by sprinkling with drinking water as indicated in the standards used. In addition to this, the evaluation of concrete bricks from the UNICON company was carried out for a subsequent comparison of results. It was observed that the bricks made with the pattern design had a compressive strength of 191 kg⁄〖cm〗^2, density 2263 kg⁄m^3, absorption 5%, thermal degradation of 11.60 g, without observing the presence of fungus, while with the replacement of 50% of the fine aggregate by cellulose filter pulp a compressive strength of 182 was obtained. kg⁄〖cm〗^2 . density kg⁄m^3,, absorption 7%, thermal degradation 13 96 g, without mushroom appearance. It was determined that the incorporation of a higher percentage of filter decreases the compressive strength by 157 kg⁄〖cm〗^2, as well as the density by 2033 kg⁄m^3, absorption by 9%, however, it increases the degradation thermal at 15.97 g and the absence of fungus is maintained. Based on the analysis of results obtained in the research, it is established that the optimal replacement percentage is 50% of cellulose filter residue with respect to the volume of the fine aggregate, this would represent 6% of cellulose filter residue and 94% of fine aggregate with respect to weight. Keywords: cellulose filter, concrete brick, recycled paper.
dc.formatapplication/pdf
dc.identifier.urihttps://hdl.handle.net/20.500.14414/22820
dc.language.isospa
dc.publisherUniversidad Nacional de Trujillo
dc.publisher.countryPE
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectTECHNOLOGY::Engineering physics::Other engineering physics
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#2.05.00
dc.title"Influencia del porcentaje de residuo de filtro de celulosa en reemplazo del valor agregado fino sobre la calidad y durabilidad en unidades de albiñalería de concreto"
dc.typeinfo:eu-repo/semantics/bachelorThesis
dc.type.versioninfo:eu-repo/semantics/publishedVersion
renati.advisor.dni80524374
renati.advisor.orcid0000-0002-6717-0501
renati.author.dni75895255
renati.author.dni70329220
renati.discipline713016
renati.jurorChávez Novoa, Danny Mesías
renati.jurorOtiniano Mendez, Santos Dionicio
renati.jurorVásquez Alfaro, Iván Eugenio
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesional
renati.typehttps://purl.org/pe-repo/renati/type#tesis
thesis.degree.disciplineIngeniería de Materiales
thesis.degree.grantorUniversidad Nacional de Trujillo
thesis.degree.nameIngeniero de Materiales
Files
Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Acuña Castañeda y Nuñez Quiroz.pdf
Size:
18.89 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: