Influencia de la densidad de corriente y ph, para evaluar la remoción del Cr+3 y DQO en efluente de etapa de curtido, mediante electrocoagulación fotovoltaica

dc.contributor.advisorMendoza Bobadilla, Jorge Luis
dc.contributor.authorDiego Pérez, Amilcar Santos
dc.contributor.authorMas Martínez, Jorge Antonio
dc.date.accessioned2019-04-16T23:55:47Z
dc.date.available2019-04-16T23:55:47Z
dc.date.issued2019
dc.descriptionThe present investigation studied the influence of pH and current density in electrocoagulation. Design parameters such as distance between electrodes, reactor volume, dimensions of the electrodes, have been defined by background. For the tests, the pH and the current density of each electrocoagulation were controlled. From the above, was obtained that at pH of 8 and current density of 28.51 mA / cm2 there was a reduction of 71.48% and 99.17% of COD and Cr3+ respectively. With the operating conditions of the data, a photovoltaic panel (PFV) was implemented to electrocoagulation, reporting COD removal results of 66.61% and 79.5% for Cr3+. In terms of energy consumption, in the EC + PFV results of 36.58 kwh/m3 were obtained, and 43.93 kwh/m3 in ECes_PE
dc.description.abstractLa presente investigación estudió la influencia del pH y la densidad de corriente en la electrocoagulación. Parámetros de diseño como distancia entre electrodo, volumen de reactor, dimensiones de los electrodos; han sido definidos por antecedentes. Para los ensayos, se controló el pH y la densidad de corriente simultáneamente en cada electrocoagulación. De lo anterior se obtuvo que a un pH de 8 y densidad de corriente de 28.51 mA/cm2 hubo una reducción de 71.48% y 99.17% de DQO y Cr3+ respectivamente. Con las condiciones de operación de los datos mencionados, se implementó a la electrocoagulación, un panel fotovoltaico (PFV), reportando resultados de remoción de DQO de 66.61% y 79.5% para Cr+3. En cuanto a consumo energético, se obtuvieron resultados de 36.58 kwh/ m3 en la EC+ PFV, y 43.93 kwh/m3 en la ECes_PE
dc.description.uriTesises_PE
dc.identifier.urihttps://hdl.handle.net/20.500.14414/12409
dc.language.isospaes_PE
dc.publisherUniversidad Nacional de Trujilloes_PE
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/2.5/pe/es_PE
dc.sourceUniversidad Nacional de Trujilloes_PE
dc.sourceRepositorio institucional - UNITRUes_PE
dc.subjectCurtiembrees_PE
dc.subjectCurtidoes_PE
dc.subjectElectrocoagulación (EC)es_PE
dc.subjectPanel fotovoltaico (PFV) cromoes_PE
dc.subjectDemanda química de oxígeno (DQO)es_PE
dc.subjectPHes_PE
dc.subjectDensidad de corriente (j)es_PE
dc.titleInfluencia de la densidad de corriente y ph, para evaluar la remoción del Cr+3 y DQO en efluente de etapa de curtido, mediante electrocoagulación fotovoltaicaes_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.disciplineIngeniería Químicaes_PE
thesis.degree.grantorUniversidad Nacional de Trujillo. Facultad de Ingeniería Químicaes_PE
thesis.degree.levelTítulo Profesionales_PE
thesis.degree.nameIngeniero Químicoes_PE
Files
Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
DiegoPerez_A - MasMartinez_J.pdf
Size:
2.67 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: