Niveles plasmaticos de glucosa en adultos mayores pertenecientes al sector Bellavista del distrito de La Esperanza - Trujillo - diciembre 2009.
No Thumbnail Available
Date
2010
Journal Title
Journal ISSN
Volume Title
Publisher
Universidad Nacional de Trujillo
Abstract
En el presente estudio se evaluaron 83 personas adultos mayores de 60 años de ambos sexos, pertenecientes al Sector Bellavista - distrito de La Esperanza - Trujillo, que participaron en forma voluntaria, aparentemente sanos y en ayunas. Se aplicó una encuesta con la finalidad de interpretar mejor los resultados; se les pesó, talló y se les midió la presión arterial. Las muestras de sangre se obtuvieron por punción venosa del antebrazo almacenándolas en vacutainers de color lila contiendo EDTA como anticoagulante, se centrifugaron a 3500 rpm durante 5 minutos, el plasma fue transvasado a viales estériles. Los niveles de glucosa en plasma fueron determinados por el método enzimático de glucosa oxidasa (GOD) y peroxidasa (POD).Las lecturas de la absorbancia se realizaron a 505 nm en un espectrofotómetro Semiautochemistry Analizer RT 19046 Kayto. El 89.2% de los participantes tuvieron un nivel de glucosa normal, 10,8 % glicemia elevada; de estos últimos el 33,3% son hombres y el 66,7 % son mujeres. Con respecto al Índice de Masa Corporal (IMC) de los participantes hiperglicémicos el 44,4% estuvieron dentro del rango normal, el 22,2 % con sobrepeso, 22,2 % con obesidad tipo 1 y 11,1% con obesidad tipo 2. De los participantes hiperglicémicos el 66,7% tuvo una presión arterial normal y el 33,3% un presión arterial elevada
Description
In the present study 83 persons were evaluated, They’ re adults major 60-year-old of both sexes, belonging to the Sector Bellavista - district of The Hope - Trujillo, which they took part in voluntary form, seemingly healthily and fasting. A survey was applied by the purpose of interpreting better the results; they were weighed, dealt and the arterial pressure measured up them.The samples of blood were obtained by venous puncture of the forearm them storing in vacutainers of color lilac contend EDTA as anticoagulant, they were centrifuged to 3500 rpm during 5 minutes, the plasma was spilt to road sterile. The levels of glucose in plasma were determined by the enzymatical method of glucose oxidasa (GOD) and peroxidasa (POD). The readings of the absorbance fulfilled to 505 nm in a spectrophotometer Semiautochemistry Analizer RT 19046 Kayto. 89.2 % of the participants had a level of normal glucose, 10,8 % high blood sugar; of the latter 33,3 % they are men and 66,7 % are women. With regard to the Index of Corporal Mass (IMC) of the participants with high blood sugar 44,4 % was inside the normal range, 22,2 % with overweight, 22,2 % with obesity type 1 and 11,1 % with obesity type 2. Of the participants with high blood sugar 66,7 % had an arterial normal pressure and 33,3 % an arterial high pressure
Keywords
Glucosa, Glucosa oxidasa, Diabetes, Peroxidasa, Análisis de sangre, Adulto mayor, Plasma