Análisis Fisicoquímico de gasa grande estéril en Hypatia S.A., 2016

dc.contributor.advisorRengifo Penadillos, Roger Antonio
dc.contributor.authorAvalos Ibañez, Katherine Lizeth
dc.date.accessioned2017-10-17T16:54:48Z
dc.date.available2017-10-17T16:54:48Z
dc.date.issued2017-09
dc.descriptionThe present report of pre-professional practices was done in Hypatia S.A and it had as purpose to do the physicochemical analysis of large sterile gauze. The sample consisted of 50 units of gauze, batch 1110506. The following physicochemical tests were applied: weight in grams per square meter, amount of warp and weft threads in 2.54 cm of gauze, dimensions, absorbance in seconds, ash, content of rayon, dry residue, acid, alkali, dextrins, fat materia and alcohol soluble dyes, as established by the Peruvian technical standard and the original laboratory analysis technique, it was obteined as resulting the conformity for each test. It is concluded that the medical material gauze large sterile folded 10 cm x 10 cm meets the specifications of the physicochemical parameters established by the Peruvian technical standard and the original laboratory technique of analysises_PE
dc.description.abstractEl presente informe de prácticas pre-profesionales se realizó en Hypatia S.A y tuvo como finalidad realizar el análisis fisicoquímico de gasa grande estéril. La muestra estuvo conformada por 50 unidades de gasa, lote 1110506. Se aplicó las siguientes pruebas fisicoquímicas: peso en gramos por metro cuadrado, cantidad de hilos en urdimbre y trama en 2,54 cm de gasa, dimensiones, absorbencia en segundos, cenizas, contenido de rayón, residuo seco, ácido, álcali, dextrinas, materia grasa y colorantes solubles en alcohol, según lo establecido por la norma técnica peruana y la técnica de análisis de laboratorio de origen, obteniéndose como resultado la conformidad para cada ensayo. Se concluye que el material médico gasa grande estéril doblada 10 cm x 10 cm cumple con las especificaciones de los parámetros fisicoquímicos establecidos por la norma técnica peruana y la técnica de análisis de laboratorio de origenes_PE
dc.description.uriTesises_PE
dc.identifier.urihttps://hdl.handle.net/20.500.14414/8933
dc.language.isospaes_PE
dc.publisherUniversidad Nacional de Trujilloes_PE
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/2.5/pe/es_PE
dc.sourceUniversidad Nacional de Trujilloes_PE
dc.sourceRepositorio institucional - UNITRUes_PE
dc.subjectControl de calidad, material médico, Gasaes_PE
dc.titleAnálisis Fisicoquímico de gasa grande estéril en Hypatia S.A., 2016es_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
thesis.degree.disciplineFarmaciaes_PE
thesis.degree.grantorUniversidad Nacional de Trujillo.Facultad de Farmacia y BIoquímicaes_PE
thesis.degree.levelTítulo Profesionales_PE
thesis.degree.nameQuímico Farmacéuticoes_PE
Files
Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Avalos Ibañez Katherine Lizeth.pdf
Size:
991.16 KB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: