Desarrollo y Validación de un método espectrofotométrico UV/Vis para perfiles de disolución temporal a pH fisiológicos de tabletas de Atenolol 100 mg

dc.contributor.advisorAlva Plasencia, Pedro Marcelo
dc.contributor.advisorSaldaña Bobadilla, Vanessa
dc.contributor.authorAnticona Polo, Santiago
dc.date.accessioned2024-12-30T17:37:01Z
dc.date.available2024-12-30T17:37:01Z
dc.date.issued2024
dc.description.abstractEl presente informe de tesis tuvo como objetivo desarrollar y validar un método espectrofotométrico UV/Vis para investigar los perfiles de disolución de tabletas de atenolol 100 mg. Se realizaron ensayos en medios de disolución con pH 1,2; 4,5 y 6,8; evaluando los parámetros de linealidad, precisión, exactitud, selectividad, robustez, estabilidad y el impacto del uso de filtro. Para ello, se empleó un equipo de disolución Sotax AT7 Smart y un espectrofotómetro UV/Visible Perkin Elmer, siguiendo las pautas de la Farmacopea de EE. UU. (USP 42), la Conferencia Internacional de Armonización (ICH) y la Asociación Española de Farmacéuticos de la Industria (AEFI). Se utilizó el aparato de paletas (tipo 2), con 900 mL de medio de disolución, a 37°C ± 0,5°C, agitación de 50 rpm y tiempos de muestreo hasta 60 minutos. Las lecturas se realizaron a una longitud de onda de 274 nanómetros. Los resultados mostraron una excelente linealidad con coeficientes de correlación y determinación superiores a 0,999 en todos los medios, junto con coeficientes de variación menores al 2% en los factores de respuesta. En exactitud, los porcentajes de recuperación oscilaron entre el 95% y el 105%, y el coeficiente de variación porcentual fue inferior al 5%. Los parámetros de precisión (repetibilidad e intermedia), robustez y el impacto del uso de filtro también demostraron una variación porcentual inferior al 2%. La selectividad presentó interferencias menores al 2%, y la estabilidad de la solución muestra fue adecuada con una diferencia absoluta inferior al 2% tras 12 y 24 horas. Se concluye que el método UV/Vis validado cumple con los requisitos de linealidad, exactitud, precisión, selectividad, robustez y estabilidad, siendo adecuado para investigar perfiles de disolución de tabletas de atenolol 100 mg
dc.description.abstractABSTRACT The present thesis report aimed to develop and validate a UV/Vis spectrophotometric method to investigate the dissolution profiles of atenolol 100 mg tablets. Tests were performed in dissolution media with pH 1.2, 4.5 and 6.8, evaluating the parameters of linearity, precision, accuracy, selectivity, robustness, stability and the impact of filter use. For this purpose, a Sotax AT7 Smart dissolution apparatus and a Perkin Elmer UV/Visible spectrophotometer were used, following the guidelines of the U.S. Pharmacopoeia (USP 42), the International Conference on Harmonization (ICH) and the Spanish Association of Industry Pharmacists (AEFI). The paddle apparatus (type 2) was used, with 900 mL of dissolution medium, at 37°C ± 0.5°C, 50 rpm agitation and sampling times up to 60 minutes. Readings were taken at a wavelength of 274 nanometers. The results showed excellent linearity with correlation and determination coefficients greater than 0.999 in all media, along with coefficients of variation less than 2% in the response factors. In accuracy, recovery percentages ranged from 95% to 105%, and the coefficient of percentage variation was less than 5%. The parameters of precision (repeatability and intermediate), robustness and the impact of filter use also showed a percentage variation of less than 2%. Selectivity showed interferences of less than 2%, and the stability of the sample solution was adequate with an absolute difference of less than 2% after 12 and 24 hours. It is concluded that the validated UV/Vis method meets the requirements of linearity, accuracy, precision, selectivity, robustness and stability, being suitable for investigating dissolution profiles of atenolol 100 mg tablets.
dc.formatapplication/pdf
dc.identifier.urihttps://hdl.handle.net/20.500.14414/23097
dc.language.isospa
dc.publisherUniversidad Nacional de Trujillo
dc.publisher.countryPE
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttps://creativecommons.org/licenses/by-nc/4.0/
dc.sourceUniversidad Nacional de Trujillo
dc.sourceRepositorio Institucional UNITRU
dc.subjectValidación. Perfiles. Atenolol. Espectrofotometría
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#3.01.05
dc.titleDesarrollo y Validación de un método espectrofotométrico UV/Vis para perfiles de disolución temporal a pH fisiológicos de tabletas de Atenolol 100 mg
dc.typeinfo:eu-repo/semantics/bachelorThesis
dc.type.versioninfo:eu-repo/semantics/publishedVersion
renati.advisor.dni18036605
renati.advisor.dni44271814
renati.advisor.orcidhttps://orcid.org/0000-0002-0009-7143
renati.author.dni44850534
renati.discipline917046
renati.jurorCastillo Saavedra, Ericson Felix
renati.jurorMarin Cacho, Fanny Teresa
renati.jurorAro Díaz, Rubén Jesús
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesional
renati.typehttps://purl.org/pe-repo/renati/type#tesis
thesis.degree.disciplineFarmacia
thesis.degree.grantorUniversidad Nacional de Trujillo. Facultad de Farmacia y Bioquímica
thesis.degree.nameQuímico Farmacéutico
Files
Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Anticona Polo Santiago_secured.pdf
Size:
2.29 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: