Desarrollo y Validación de métodos espectrofotométricos UV/VIS para la cuantificación de Rifampicina, Isoniazida y Pirazinamida en estudios de bioexención

dc.contributor.advisorAurora Prado, María Segunda
dc.contributor.advisorAlva Plasencia, Pedro Marcelo
dc.contributor.authorSaldaña Bobadilla, Vanessa
dc.date.accessioned2024-09-13T17:59:33Z
dc.date.available2024-09-13T17:59:33Z
dc.date.issued2024
dc.description.abstractLa bioexención se caracteriza por la sustitución de estudios de bioequivalencia por pruebas de disolución in vitro, basándose en el Sistema de Clasificación Biofarmacéutica. Estos estudios necesitan métodos de cuantificación validados para dar confiabilidad a los resultados. El objetivo de esta investigación fue desarrollar y validar métodos espectrofotometricos UV/VIS para la cuantificación de Rifampicina, Isoniazida y Pirazinamida para estudios de bioexención. La especificidad, linealidad, rango, exactitud, precisión, estabilidad de la solución analítica, prueba de filtro, límites de detección y cuantificación fueron evualuados según los estándares establecidos por los lineamientos de la International Conference on Harmonisation y la Farmacopea de los Estados Unidos. Se utilizaron diferentes condiciones de disolución y tiempos de muestreo. Se determinaron las longitudes de onda de máxima absorbancia para los tres medicamentos en los tres medios de disolución. El método fue lineal en los rangos de concentración estudiados. Los límites de detección y cuantificación estuvieron dentro de lo esperado. Los valores recuperados se encontraron entre 95%-105%. No se observó interferencia de los placebos. Los valores de coeficientes de variación porcentual fueron menores al 2% para la precisión. Para la robustez se evaluaron diferentes condiciones como diferentes longitudes de onda, cambios en la concentración y los filtros Whatman No 40, No 41, No 42; los cuales no modificaron la respuesta del método. Las muestras se conservaron sin cambios durante las 6 horas de trabajo a 25 ºC. Sin embargo para rifampicina e isoniazida estas no fueron estables a 24 horas. Los métodos fueron lineales, exactos, específicos y precisos en los rangos de concentración estudiados y en los tres medios de disolución siendo apto su uso para estudios de bioexención.
dc.description.abstractBiowaiver is characterized by the substitution of bioequivalence studies by in vitro dissolution tests, based on the Biopharmaceutical Classification System. These studies need validated quantification methods to give reliability to the results. The objective of this research was to develop and validate UV/VIS spectrophotometric methods for the quantification of Rifampicin, Isoniazid and Pyrazinamide for biowaiver studies. Specificity, linearity, range, accuracy, precision, stability of the analytical solution, filter test, detection and quantification limits were evaluated according to the standards established by the guidelines of the International Conference on Harmonisation and the United States Pharmacopeia. Different dissolution conditions and sampling times were used. The wavelengths of maximum absorbance were determined for the three drugs in the threedissolution media. The method was linear in the concentration ranges studied. The detection and quantification limits were within those expected. The recovered values were between 95%-105%. No interference from placebos was observed. The coefficients of variation percentage values were less than 2% for precision. For robustness, different conditions were evaluated such as different wavelengths, changes in concentration and Whatman filters No. 40, No. 41, No. 42; which did not modify the response of the method. The samples were preserved without changes during the 6 hours of work at 25 ºC. However, for rifampicin and isoniazid, these were not stable at 24 hours. The methods were linear, exact, specific and precise in the concentration ranges studied and in the three-dissolution media, being suitable for use in biowaiver studies.
dc.formatapplication/pdf
dc.identifier.urihttps://hdl.handle.net/20.500.14414/22323
dc.language.isospa
dc.publisherUniversidad Nacional de Trujillo
dc.publisher.countryPE
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/
dc.sourceUniversidad Nacional de Trujillo
dc.sourceRepositorio Institucional - UNITRU
dc.subjectMedicamentos antituberculosos
dc.subjectFármaco disuelto
dc.subjectBioequivalencia
dc.subjectSolubilidad
dc.subjectEspectrofotometría
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#3.01.05
dc.titleDesarrollo y Validación de métodos espectrofotométricos UV/VIS para la cuantificación de Rifampicina, Isoniazida y Pirazinamida en estudios de bioexención
dc.typeinfo:eu-repo/semantics/doctoralThesis
dc.type.versioninfo:eu-repo/semantics/publishedVersion
renati.advisor.dni17844238
renati.advisor.dni18036605
renati.advisor.orcidhttps://orcid.org/0000-0002-9956-9410
renati.advisor.orcidhttps://orcid.org/0000-0002-0009-7143
renati.author.dni44271814
renati.discipline917038
renati.jurorGonzález Blas, María Virginia
renati.jurorRengifo Penadillos, Roger Antonio
renati.jurorRuíz Reyes, Segundo Guillermo
renati.jurorAurora Prado, María Segunda
renati.levelhttp://purl.org/pe-repo/renati/level#doctor
renati.typehttp://purl.org/pe-repo/renati/type#tesis
thesis.degree.disciplineDoctorado en Farmacia y Bioquímica
thesis.degree.grantorUniversidad Nacional de Trujillo. Escuela de Posgrado
thesis.degree.nameDoctora en Farmacia y Bioquímica
Files
Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Saldaña Bobadilla, Vanessa.pdf
Size:
908.73 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: