“Reducción de iones cromo en efluentes galvanoplásticos por electrocoagulación al variar tipos de electrodos metálicos y densidad de corriente”

dc.contributor.advisorOtiniano Mendez, Santos Dionicio
dc.contributor.authorBaltazar Melendez, Gregory Manuel
dc.contributor.authorRodriguez Marin, Emerson Manuel
dc.date.accessioned2024-11-06T20:24:59Z
dc.date.available2024-11-06T20:24:59Z
dc.date.issued2024-11
dc.description.abstractEn este estudio se utilizó el principio de electrocoagulación para investigar los efectos de la densidad de corriente y los tipos de electrodos metálicos en la reducción de los iones de cromo presentes en una solución con cromo hexavalente a 70 ppm, se conoce que la contaminación del agua relacionada con la actividad industrial es un grave problema mundial. Según estimaciones de la Comisión Internacional para la Conservación del Aire y del Océano (ICACO), una fracción considerable de los contaminantes que acaban en el océano proceden de fuentes terrestres, principalmente industriales, por ello en esta investigación se evaluaron los efectos de la densidad de corriente (7, 10 y 15 mA/cm2 ) y tres tipos diferentes de configuraciones de electrodos: cátodo de hierro, ánodos de hierro, acero inoxidable y aluminio de (10 x 12 x 0.2) cm, por lo que se emplearon 4 electrodos por ensayo; esto se hizo para un reactor de electrocoagulación en batch con unas dimensiones de (13 x 13 x 15) cm, en el que se realizaron 27 ensayos con una duración constante de la prueba de 30 minutos. Los resultados mostraron que el aumento de la densidad de corriente aplicada entre 7 y 15 mA/cm2 aumenta el porcentaje de cromo eliminado del efluente galvánico; se observó un patrón similar con el tipo de electrodo metálico, fue la configuración hierro-hierro, que produjo el mayor porcentaje de eliminación (93,40%) a una densidad de corriente de 15 mA/cm2 , mientras que la configuración hierro-aluminio produjo el menor porcentaje de eliminación (78,85%) a una densidad de corriente de 7 mA/cm2 . Un análisis de varianza con un nivel de confianza del 95% confirma los resultados, que indican que los tipos de electrodos metálicos y la densidad de corriente tienen un impacto sustancial en el porcentaje de cromo eliminado del efluente galvánico. Palabras clave: Electrocoagulación. Densidad de corriente, Cromo hexavalente ABSTRACT In this research, the principle of electrocoagulation was used to investigate the effects of current density and types of metal electrodes on the reduction of chromium ions present in a solution containing hexavalent chromium at 70 ppm. Water pollution related to industrial activity is known to be a serious global problem. Industrial activity is responsible for a considerable part of water pollution. According to estimates by the International Commission for Air and Ocean Conservation (ICACO), a considerable fraction of the pollutants that end up in the ocean come from land-based sources, mainly industrial, so this research evaluated the effects of current density (7, 10 and 15 mA/cm2 ) and three different types of electrode configurations: iron cathodes and iron, stainless steel and aluminum anodes (10 x 12 x 0.2) cm, so 4 electrodes were used per test; This was done for a batch electrocoagulation reactor with dimensions of (13 x 13 x 15) cm, in which 27 tests were carried out with a constant test duration of 30 minutes. The results showed that increasing the applied current density between 7 and 15 mA/cm2 increases the percentage of chromium removed from the galvanic effluent; a similar pattern was observed with the type of metal electrode, it was the iron-iron configuration, which produced the highest percentage removal (93.40%) at a current density of 15 mA/cm2 , while the iron-aluminum configuration produced the lowest percentage removal (78.85%) at a current density of 7 mA/cm2 . An analysis of variance at 95% confidence level confirms the results, which indicate that the types of metal electrodes and current density have a substantial impact on the percentage of chromium removed from the galvanic effluent. Key words: Electrocoagulation, Current density, Hexavalent chromium.
dc.formatapplication/pdf
dc.identifier.urihttps://hdl.handle.net/20.500.14414/22826
dc.language.isospa
dc.publisherUniversidad Nacional de Trujillo
dc.publisher.countryPE
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectTECHNOLOGY::Engineering physics::Other engineering physics
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#2.05.00
dc.title“Reducción de iones cromo en efluentes galvanoplásticos por electrocoagulación al variar tipos de electrodos metálicos y densidad de corriente”
dc.typeinfo:eu-repo/semantics/bachelorThesis
dc.type.versioninfo:eu-repo/semantics/publishedVersion
renati.advisor.dni18205201
renati.advisor.orcid0000-0003-1417-8021
renati.author.dni71327790
renati.author.dni71232509
renati.discipline713016
renati.jurorDíaz Díaz, Alex Fabián
renati.jurorVizconde Poemape, Hebert Gustavo
renati.jurorOtiniano Mendez, Santos Dionicio
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesional
renati.typehttps://purl.org/pe-repo/renati/type#tesis
thesis.degree.disciplineIngeniería de Materiales
thesis.degree.grantorUniversidad Nacional de Trujillo
thesis.degree.nameIngeniero de Materiales
Files
Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Baltazar Melendez y Rodriguez Marin.pdf
Size:
13.33 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: